AMP-50 Area Monitor

The AMP-50’s detector features a linear response from 10 µR/h to 4 R/h (0.1 µSv/h to 40 mSv/h ).
The probe head may be located near a filter cube, rad waste stream, resin tank, or even inside the fuel pool (to take advantage of waterproof characteristics). The AMP-50 may be used in one of 2 ways: by locally reading the smoothed digital display via the hand-held meter, or by connecting the meter to a Remote Monitoring System (e.g. wired DDC 16 or wireless WRMPlus) and TeleMap or connected directly to RS-232 computer input (using the RS-232 cable)
Features
Wide range response from 10 µR/h to 4 R/h (0.1 µSv/h to 40 mSv/h).
Ruggedized construction, waterproof detector housing and cable
Quick-connect connectors allow customization of cable length and facilitate easy de-contamination
Built-in RS-232 communication connection for use with Area Monitor or WRM transmitter
"Smoothed" digital display offers accurate, stable readings
User-selectable internal alarm threshold
Applications
Area monitoring of low dose rate areas (ISFSI -Independent Spent Fuel Storage Installations)
Low-level radioactive waste material surveillance
Facility & site boundary surveillance
Emergency Response surveillance
Control shipping of radioactive material
Environmental monitoring
Outdoor area monitoring
Underwater surveys
Alara waiting areas
Technical Description
The Area Monitor Probe (AMP-50) is a low-range GM tube-based detector designed to be continuously used in areas where exposure levels are required to be monitored.
The instrument consists of three parts: the Meter box, which includes the display unit, operating pushbuttons and detector’s electronics; The probe head, which contains the GM Tube; and the connecting cable, which is fitted with quick-connect-type connectors at each end. The AMP-50’s connections and probe head feature watertight sealing to allow for use in underwater applications.
Specifications
|
Detector: |
|
(ZP-1201, or equivalent) |
|
Energy Range: |
|
50 KeV to 2 MeV. |
|
Measuring Range: |
|
10µ R/h to 4 R/h (0.1 µSv/h to 40 mSv/h) |
|
Sensitivity (137Cs): |
|
17 cps per mR/hr |
|
Accuracy: |
|
±10% of reading within measuring range |
|
Units: |
|
mR/h and mR or m Sv/h and m Sv |
|
Controls: |
|
Four key keypad with positive feedback. Key combinations for programming operating parameters. |
|
Power Source: |
|
One 9-volt cell battery or external 9V power supply, 50 hours minimum continuous operation, using an alkaline battery (speaker off) |
|
Display : |
|
LCD Display showing: Detector failure, Low battery, Overflow, Threshold |
|
Temperature Range: |
|
Operation: -10° C to +50° C (15° F to 122° F) |
|
Humidity Range |
|
40% to 95% RH (non condensing) |
|
Casing Material: |
|
Meter: Aluminum |
|
Dimensions: |
|
Meter: 2.7” wide, 4.7” high, 1.25” deep |
|
Weight: |
|
Meter: 340 g (0.76 lbs) including battery |
|
Std. Cable Length: |
|
25 ft. |
|
Max. Cable Length: |
|
350 ft. |
|
Expected detector lifetime: |
|
|
Accuracy, range and sensitivity details are related to 137Cs
Ordering Information
AMP 50 (mR/h) (incl. 7m cable) BAK-0060
AMP 50 (uSv/h) (incl. 7m cable) BAK-0070
Back to top