RAM DA 2000

The RAM DA 2000 Series is available with dual, wide range internal GM detectors and/or a choice of nine external interchangeable detectors suitable for alpha, beta, low or high-energy gamma and X-ray detection. These quality, plug-in detectors automatically recalibrate and select the appropriate readout units when connected to the RAM DA 2000 Monitor. The low voltage, digital interface between the external detector and RAM DA 2000 Monitor ensures excellent signal-to-noise ratios, high stability and a capability for extended cable lengths.
RAM DA-2000: Monitor without internal detector
RAM DA 3-2000: Monitor with internal detector
Features
Large, easy to read, LCD display with continuous ranging, digital readout, analogscaled bar graph and alpha-numeric parameter indicators
Simple operation using five water resistant push buttons
Readout of dose rate and accumulated dose, counts, counts per minute, counts per second and scaled counts using time presets
Dose units of either mR or µSv
User programmable alarm thresholds
Audible count rate indication
Smart software provides fast, yet stable response
Dead time correction
Alarms for detector overflow, low battery and detector failure
Automatic self diagnostic routines for monitor and detectors
Automatic re-calibration with each change of detector
Various types of detectors including GM, sodium iodide, alpha and ion chamber
Display illumination
Durable, splash resistant case
On-board, clock calendar
Alarm relays to trigger external devices
Non-volatile storage of up to 380 records comprising ID, date and time stamp with dose data
Computer interface for serial data transfer
Optional built-in laser scanner
Compatible with SMARTS and RMV Software Packages Specifications
|
Display Type: |
Large 4 digit LCD with a 20 segment, autoranging, analog scaled bar graph and a 7 segment display for detector identification. |
|
Display Data: |
Measuring units |
|
Measuring Units: |
cps, cpm, counts, dose rate (µSv/hr or mR/hr) and accumulated dose (µSv or mR). |
|
Audio: |
Piezo electric element |
|
Power Source: |
Three, 1.5V 'C' cell alkaline batteries. Provides minimum of 150 hours continuous use (without illumination) with internal detector or 100 hours continuous use with external detector |
|
Temperature Range: |
Operation: -10oC to +50oC (15oF to 122oF) |
|
Humidity Range: |
10% to 95% RH (non condensing) |
|
Case: |
High impact ABS |
|
Dimensions: |
14.2cm x 24.4cm x 11.5cm (5.6" x 9.6" x 4.5") |
|
Weight: |
1.46 kg (3.22 lbs) - includes batteries and internal detector |
|
Internal Detector Option: |
|
|
Measuring Range: |
0.5µSv/hr to 1 Sv/hr (50 µR/hr to 100R/h) |
|
Display Range: |
0.01µSv/hr to 1 Sv/hr (1 µR/hr to 100R/hr) |
|
Accuracy: |
±10% of reading |
|
Energy Response: |
±30% over the range of 50keV to 1.3MeV |
|
Angular Dependence: |
Less than ±20% for ±45o of preferred direction |
|
RAM DA 2000 - Additional Feature Specifications: |
|
|
Memory: |
NV SRAM, 347 records, optional 1415 records |
|
Communication: |
Serial port (RS-232), DB9F connector |
|
Relay Contacts: |
Threshold alarm (N/O) Alarm failure (N/O) - DB9M connector |
|
Laser Option: |
Class II, max. power 1.0mW |
Ordering Information
RAM DA-2000 (µSv/h) BAK-1640
RAM DA-3-2000 (µSv/h) BAK-1670
RAM DA Cable (coiled) BAK-0490
RAM DA Cable (straight) BAK-0510
Note: Specifications subject to change without notice.