Home page › RAM GENE-1 mark II

RAM GENE-1 mark II

The RAM GENE-1 mark II,designed for work in extreme conditions, features

a ruggedized casing and backlight and contains a specially designed energy

filter embedded in the cap for dose rate radiation monitoring according to

Ambient Dose Equivalent, with the additional flexibility of a contamination

meter.

The RAM GENE-1 is equipped with a recessed, internal GM pancake

detector using a thin mica window protected by a stainless steel screen.

The transition between measuring dose rate radiation and contamination is

achieved by simply removing or placing the plastic cap.

 

Features

• Large, four digit, continuous ranging, LCD display
• Simple, three key operation
• Large 1.75" pancake GM detector
• Suitable for alpha, beta or gamma contamination detection
• Unit readouts of count rate (CPS in contamination mode and (µSv/hr) in dose mode.
• Audible and visual (LED) count rate indication
• Smart software provides fast, yet stable response
• Dead time correction
• Alarms for overflow, low battery and detector failure
• Automatic self diagnostic routines
• Durable case with splash resistant keypad

Technical Data

Display:

Large, four digit, continuous ranging LCD readout for display of count rate, dose rate, overflow, low battery, and detector failure.

LED:

Flashing count rate indication with Audio Piezo electric element synchronized with count LED.

Units:

Counts per second (CPS) or counts per minute (CPM) and µSv/hr or mR/hr.

Controls:

Three key keypad with positive feedback for ON/OFF Key combinations for selecting count rate or dose rate unit displays.

Power:

Standard 9V alkaline battery - provides approximately 50 hours continuous use with speaker off. Automatic battery check under full load.

Detector:

1.75" Pancake GM tube - LND73118 or equivalent

Window :

Mica, 1.5 - 2.0 mg/cm2 protected by stainless steel mesh.

Count Range:

0 - 42,000 cps

Sensitivity:

Approximately 5.8 cps/µSv/hr (58 cps/mR/hr) - 137Cs

Measuring Range:

0.05µSv/hr to 7mSv/hr (5µR/hr to 700mR/hr)

Display Resolution:

0.01µSv/hr (0.001mR/hr)

Background:

0 - 1 cps

Temperature Range:

Operation: -10oC to +50oC (15oF to 122oF)

 

Storage: -20oC to +60oC (-5oF to 140oF)

Humidity Range:

40% to 95% RH (non condensing)

Case:

High impact ABS

Dimensions:

11cm x 6.7cm x 7.4cm (4.3" x 2.6" x 2.9")

Weight:

0.565 Kg (1.25 lbs)

Variation of Response with Particle Energy

Emax < 0.2 MeV – 14C

Emax between 0.2 MeV and 0.5 MeV – 147Pm and 60Co

Emax > 0.5 MeV - 36Cl and 90Sr/90Y
 

Performance (surface sensitivity - in contact) Beta Emitting Isotopes

Isotope

Emax (keV)

2p Efficency(%)

Sensitivity cps/Bq/cm2

MDLBq/cm2

14C

156

3

0.25

9.0

35S

167

8

0.65

3.7

147Pm

224

15

1.25

2.0

99Tc

290

20

1.75

1.5

90Sr + 90Y

580 + 2280

50

8.50

0.3

36Cl

714

45

3.50

0.7

210Pb

1160

50

4.00

0.6

32P

1710

70

5.50

0.5

Additional radionuclides

Isotope

Sensitivity cps/Bq/cm2

MDL Bq/cm2

99mTc

0.45

5.5

125I

0.04

63.0

131I

3.00

0.8

230Th

1.10

2.5

241Am

1.10

2.5

 
Compliant to IEC 60846 and IEC 60325 for ambient dose equivalent and contamination monitoring
 

 

Ordering Info:

RAM GENE-1 (uSv/h + CPS) BAK-1880

RAM GENE-1 (uSv/h + CPM) BAK-1885

RAM GENE-1 (mR/h + CPS) BAK-1890

RAM GENE-1 (mR/h + CPM) BAK-1895

RAM GENE-1 ERK Kit incl. suitcase, manual, filter BAK-1380

 
RAM GENE-1 Test Report


Back to top